Version 3.11

New features

  • Added background changes to support improved connectivity performance through Phason Web Services in future updates.

Improvements

  • Improved handling of USB-related issues to prevent them from interfering with network connectivity or the unit's startup process.
  • Device Hostname generation is now more consistent and reliable, reducing instances where the hostname could change and interfere with access through Phason Web Services.
  • Fixed an issue where the Device ID could display incorrectly on the About screen.
  • The Site Name field in Device Information is now populated by default. An empty Site Name could lead to connectivity issues.
  • Addressed an issue where a white screen displaying the message, "Please check your device name or refresh to try again," could appear when accessing the control. This issue prevented users from logging in.

Go to top

Version 3.10

New features

  • RM-2 and RM-4 relay outputs can now use other relay outputs to drive their modifier conditions. For example, a relay can be set to a specific output state when another designated relay is on.

Improvements

  • The maximum drying time for Air Curtains has increased from 120 seconds to 250 seconds.
  • The BinTrac Low Feed Alarm now clears correctly.
  • My Report has been improved:
    • Duplicated probes no longer appear in the setup menu.
    • Duplicated charts no longer appear in the report.
    • Missing reports and report labels now display correctly.
  • The BinTrac Feed Consumption section now displays correctly.
  • Equipment names containing an ampersand (&) are now selectable in Output Charts, Output Reports, and Output Runtimes.
  • The Group Reading value now displays correctly in Curtain Settings.
  • VAC-1 Low Current Alarms no longer trigger when the output is at 0%.
  • Auger Manager icons are now functional in Custom Views.
  • Target Value lines now display correctly in Group Charts and My Report.
  • ACT-1T improvements:
    • The Automatic Reset Low Temperature check no longer triggers at unexpected times and temperatures.
    • Automatic Reset Active Start and End times now save the correct hour values.
    • The module no longer enters Fallback Mode unexpectedly.
  • Water Meter functions have been improved:
    • Home screen icons now show the correct value.
    • The Water Consumption Report now displays correctly.
    • The Water Meter pop-up now includes Consumption Per Animal.
  • A warning now appears when switching input configurations between Feed Loop Groups and Equipment Groups.
  • Modifiers using DOL-114 Temperature Inputs now convert between Celsius and Fahrenheit correctly.

Go to top

Version 3.09

Improvements

  • Fixed an issue where some Inputs incorrectly displayed a reading of 0 on their widget icons.
  • Feed Loop Low Current Alarms now trigger under the correct conditions and use the correct alarm set points.
  • Fixed an issue where Feed Loops using external current sensors could occasionally lose communication or stop running properly.
  • Removed the Alarm Settings menu from Feed Loop relays when an external current sensor is used. The alarms can now be accessed through the external current sensor’s icon, which has been added to the relay’s menu.
  • Resolved an issue where Water Meter input widgets could become invisible.

Go to top

Version 3.08

New features

  • The Relative temperature alarms -- when enabled, the high and low temperature alarms will be automatically adjusted any time the master set point for the group changes.
  • A Daily high and low readings for equipment groups now display on the group's widget menu.
  • A In the Auger Manager, main augers now have their own Cycle On Delay. The range is 0 seconds to 300 minutes.
  • A VDC-4 outputs can now have relays drive its modifier conditions. For example, setting the VDC-4 to a specific output if a designated relay is on.
  • A Growth Curve information can now be read through the key-based API. See api.test.phason.ca/v1.0.3 for details.

Improvements

  • The highlighting in the VentGrid Settings menu now takes into account the hysteresis between steps.
  • SMS alerts have been modified. The link to the controls has been removed to help prevent messages from being cut off or blocked by some providers. We are looking into a solution that will allow links and work with all providers.
  • The water meter widget's status display now consistently shows the correct total.
  • An issue where water consumption charts would occasionally not display data has been fixed.
  • A situation where view-only users could make changes has been fixed.

Go to top

Version 3.07

New features

  • The Auger Manager allows you create up to seven Auger Groups. An Auger Group controls one or more feed augers in coordination with each other.
  • A Notification Center has been added for users with administrator access. After an administrator logs in, any unread notices will display.
  • Feed Loop systems can now use Current Sense inputs connected to an IN-4 for current sensing.
  • A light purple widget background has been added for outputs. An output widget with a light purple background means the output is in its fallback state, likely caused by an error in the group reading or by a module communication error.
  • Misting and fogging can now be added to THI groups.
  • Misting and fogging is now available in the Phason API. See api.phason.ca for details.
  • Lighting and Timed Events support has been added to the API. See api.phason.ca for details.
  • The Feed Loop Feed Proximity Sensor alarm can now be disabled from the Feed Loop menu. When disabled, the system will behave as if the sensor was tripped at the end of the cycle, even if there was no trip event. No alarm will be generated.
  • The control's Device ID has been added to the About screen so that API users can easily reference it.

Improvements

  • Relays set to timed manual can now be set to a maximum of 3 hours (180 minutes).
  • Synchronization with the Cloud Database has been improved.
  • Remote connectivity has been improved. This resolves connection issues that occasionally occurred when connecting remotely through a browser or using mobile app.
  • Input and VAC-1 output alarm screens now update their current readings in real-time.
  • The Structure screen now shows the Rooms tab upon entry.
  • The zoom level of the mobile and Phason Connect App has been corrected.
  • The number of decimal places is now consistent across Group Reports, Input Reports, Output Reports, and the Auditor Report.
  • An issue where equipment appeared to be configured as both cooling and heating has been corrected.
  • An issue with air curtain ordering has been corrected.
  • Inputs in the Maintenance Report now have the correct highlight color when Maintenance is not yet needed.
  • Multiple relays in a VentGrid that incorrectly displayed on separate rows now display properly.
  • New devices are now being properly added to Web Services accounts from new installations.
  • Current readings for RM-2 modules are now included in API data.
  • The "My Report" temperature limits have been corrected.
  • An issue where Installer Menu options were missing has been fixed.
  • Equipment Groups, Inputs, and Outputs with commas in their names now display consistently and be configurable.
  • Tiles in the misting and fogging menu are now sorted alphabetically and are scrollable. Note that you can assign a maximum of 16 relays to one misting group.
  • The screensaver option has been removed due to some users reporting that the control would not wake up from the screensaver.

Go to top

Version 3.06

New features

  • There is now support for the new DOL 119 CO2 sensor. Both the 10000 ppm and 5000 ppm inputs may be used.
  • RM-4 relays can now be linked to a Current Sense connected to an IN-4. This allows a relay to work with high current alarm shutoff.
  • The new ACT-1T Actuator Module with timed feedback is now available. It includes the following features:
    • Current monitoring on the open and close relays
    • Timed feedback for position determination
    • Automatic reset — you can configure it to calibrate after a specific number of movements during your selected times of the day. There is an option to disable automatic reset during cold weather.
  • Current Sense modifiers are now available for all types of outputs.
  • An application programming interface (API) is now available. For information, visit .

Improvements

  • Actuators connected to an ACT-1T Timed Actuator Module now use an automatic reset instead of automatic calibration. An automatic reset periodically fully opens or fully closes the actuator to reset its position to 0% or 100%. It can also be run manually.
  • The update process has been improved to prevent a rare issue where specific module arrangements and configurations caused the update to stall.
  • The automatic reset can now run when the outdoor temperature is less than the set point instead of above it.
  • The influence modifier will now update its effect consistently when the group reading of the modified output changes.
  • The calibrate actuator option can now be accessed correctly in the Actuator Settings screen.
  • Controls with version 3.06.02 and newer will automatically check for online updates.
  • Wind speed readings now have a minimum of 0 mph instead of 2.4.
  • All reports are now correctly displaying data.
  • Water inputs can now be selected for the Water Consumption Report.
  • ACT-1 and ACT-1T feedback calibration results now display more reliably.
  • Hysteresis now works correctly in secondary modifiers for VDC-4, VAC-1, ACT-1, ACT-1T, and VCM-DC modules.
  • Alarms and reports can now be generated when there are no regular equipment groups. This allows controls with only feed loops and/or the Auger Manager to use the alarms and reports.
  • The Max Runtime for feed loops that are in schedule mode is now editable. This allows you to set a limit on test cycles. The Max Runtime can be edited in the test menu.
  • Output alarms in the Alarm Message Log now show the group of the output that is alarming.
  • Reports now correctly display items with certain special characters.
  • Dropdown menus in the Maintenance Schedule and the Alert Schedule have been improved.
  • The calibrated ranges of actuators with potentiometer, voltage, or timed feedback are now visible in their calibration screen.
  • Improvements have been made to VAC-1 outputs to prevent abnormal motor behaviour.
  • VCM-DC Feedback Sensor alarms will no longer trigger when in Gusty Mode.
  • There have been several improvements to reports.
  • In the Room Management screen, the curve name now displays below "Assign Curve" if a curve is currently assigned.
  • Input charts and reports now display correct volume totals for water meters.
  • The Water Consumption Report now displays the correct selectable inputs.
  • There have been many additional improvements and fixes for charts and reports.
  • In feed loops, the maximum value for the input alarm delay has been increased to 7200 seconds (2 hours).

Go to top

Version 3.05

Improvements

  • There is a new Setup Wizard available to guide you through the initial setup of new installations.
  • You can now use AutoFlex Connects with Protect Connect.
  • When viewed in a web browser, AutoFlex Connect now resizes to fit the browser window.
  • An evaporative cooling modifier has been added to VentGrid. The modifier allows you to reduce the ventilation rate when a cooling duty cycle or evaporative cooling cycle is active.
  • You can now configure feed loop tests to ignore the actuator drop.
  • You can now use timed overrides with VAC-1 and VDC-4 modules.
  • Configurable fallbacks have been added for VentGrid and for each output in traditional staged mode. AutoFlex Connect will use the fallback configuration if there is no valid group reading or there are communication issues.
  • The maximum duration for feed loop duty cycles been increased from 240 to 600 minutes.
  • The default for VentGrid bandwidth has decreased from 10 to 4°C.
  • Manager-level users can now access the Room Management screen to change set points and curve days.
  • Air Curtain overrides now happen immediately on individual blowers instead of waiting for blower 1 or the Blower Delay. When the last remaining blower has been set to Auto, all blowers will shut off briefly before restarting the inflation sequence from the beginning.
  • The RM-2 high current shutoff is now forced to be disabled when the high alarm is disabled. The shutoff is automatically enabled when the high alarm is enabled but you can change it to disabled.

Go to top

Version 3.04

New features

  • Current monitoring
    • You can set up an Input Module to monitor the new Current Sense 2 accessory as an input type.
    • The current range can be 0-10, 0-20, or 0-50 amps.
  • A duty cycle output option has been added to fixed stage outputs in the ventilation grid.
  • Herd information
    • Herd information can now be entered at an AutoFlex.
    • The Herd Report and Audit Report can now be viewed based on population.
  • All output data is now saved to the Phason Cloud.

Changes

  • The wind direction secondary modifier is now 180 degrees, rather than the previous 90.
  • The room setting mode can now be set to change on specific dates and can be overridden for a set duration.
  • Prevents false alarm when booting up with poor internet.
  • Added improved database maintenance to reduce memory usage and connection errors.

Go to top

Version 3.03

New Features

  • Feed loop control
    • Feed Loop Kit (model AFX-FEED-LOOP)
      • –LOOP-DRIVE module for controlling the auger and chain
      • –LOOP SENSE drive for monitoring safety and proximity sensors
    • Duty cycle and timed event modes
    • Current management and alarms
    • Optional actuator control for feed drops
  • Outdoor temperature compensation
    • Available in VentGrid and temperature groups
    • Adds an offset to the high temperature alarm when the outdoor temperature is higher than can be maintained.
    • Helps prevent unnecessary alarms on hot days
  • Actuator Module with DC feedback (model ACT-1V)
    • One open and one close relay
    • Feedback input for 0 to 10 V DC signal
  • Installer menu
    • Provides easy access to configuration and maintenance items

Changes

Improvements to reports

Go to top

Version 3.02

New Features

VentGrid
  • Combi table ventilation method
  • Provides smoother transitions between stages
Translation
  • French is now available
  • Other languages to follow
Relay stagger
  • Allows you to set the startup delay for relays
  • Prevents relays from all switching on at the same time when AutoFlex Connect starts
Tunneling
  • An improved, easier way to set up remote access
  • Allows those behind firewalls or with restricted internet providers to remotely access their Connect devices
  • Does not require special router configuration to get access
Wi-Fi network detection and strength indicator
Manual override for inputs
Ability to assign inputs to multiple equipment groups
Fifth motor curve for VAC

Changes

Rooms and equipment groups replace zones
  • A more logical way to organize and control equipment
  • Rooms contain equipment groups
  • Equipment groups contain similar types of equipment
Web Services and Play Store device app improvements
  • Automatic login to Connect devices from Web services and device app
  • Ability to change your PIN on all Connect devices from Web services and device app
  • General user interface and functional improvements
General stability and user interface improvements

Go to top

Version 2.08

New Features

VCM-DC Variable Chimney Module

The Variable Chimney Module has two 0 to 10 VDC outputs, one for a fan and one for a damper, and a measuring fan input. You can configure chimney fans to be controlled with or without feedback from a measuring fan.

Go to top

Version 2.07

New Features

Air curtains

Air curtain support has been added.

  • Air curtains use Relay Modules to switch blowers on and off to inflate and deflate the air bags.
  • Air curtain drying, deicing, and minimum ventilation can be set up for all air curtains in an equipment group.
  • There can be a maximum of 16 air curtains per AutoFlex.

Go to top

Version 2.06

New Features

Secondary Modifier Types

There are two new types of secondary modifiers:

  • And
    And allows you to modify outputs based on two different conditions.
  • Influence
    Influence allows you to increase or decrease variable output between a start and an end point. Influence modifiers can only be used with variable outputs or actuators with feedback.
Variable Runtime

Runtime has been added to the variable output menu.

Relay On Delay

When a relay reaches its setpoint, the relay will wait the set number of seconds before turning on.

Release Version

The overall version has been added to the About screen to make it easier to find.

Power Supply Version

The power supply version has been added to the About screen to make it easier to find.

Version History

Previous version changes can now be found at the bottom of the What's New screen.

Variable DC Output Alarm

If enabled, an alarm is triggered when the expected output of a Variable DC does not match the actual output.

USB Missing

If the control cannot detect the USB stick, an indicator displays in the top right corner.

Hysteresis Values

Hysteresis is now available for for CO2, ammonia, and lux.

New Input Types
  • Barometric Pressure
  • Wind Direction
  • Wind Speed
New Reports
  • Output chart with and without current (amperage)
  • Relay event chart with and without current
  • Equipment group Stage Chart

Changes

Sync Time

It is now easier to select the year and month.

E-mailed Maintenance Report

The e-mailed Maintenance Report has been improved to provide better viewing on a phone or in a web browser.

Device Information

When entering device information, site and device name are now required fields.

Followers

The list of followers is now alphabetical.

Analytics

Device and site name have been added to all reports to more easily identify which device they are from.

Go to top

Version 2.05

Changes

Power Supply

There is an important power supply update that will improve stability and performance. Phason highly recommends you update all your AutoFlex Connect controls to take advantage of the improvements.

Go to top

Version 2.04

New Features

RM-2 Relay Module
  • The RM-2 has two high-capacity, general-purpose relays, each with current sensing
  • Current monitoring alarms can be enabled independently for each relay.
Maintenance Report
  • The Maintenance Report lists all equipment that require service, and when the next service is due.
  • Service options can be configured for all equipment.
  • The Maintenance Scheduler allows you to configure Maintenance Reports to be e-mailed automatically, on a weekly or monthly basis.
My Report E-mail

Every day at 9am, every user who has at least one piece of equipment in their report will receive an e-mail of their report.

Reinstall Update

The ability to re-run the previous update. Use this if you are installing a new or replacement module and need to update the firmware.

Target Values
  • Target values have been added to all inputs and equipment groups.
  • Target values are desired ranges that help show the accuracy of the temperature (or other measured condition) on the reports.

Changes

Background

The background image has been changed to a new, sleek version.

Reports
  • Heat mat temperatures are available in My Report.
  • Equipment groups are available in My Report.
  • RM-2 amperage readings are available in the Output Readings Report.
  • If no data is available, the chart will not display. Instead, a "No data" message will display.
Equipment screens

Equipment screens have been reorganized to make them more consistent and easier to use.

Hardware Configuration

If AutoFlex detects a module with outdated firmware, the system will prompt to re-run the previous update.

Fixes

Input jumper images

An issue where an incorrect jumper image could appear for DOL-15 Temperature Sensor has been fixed.

Alarm history

A problem with the alarm history has been fixed. The problem was when more than 3,000 alarms had occurred within the duration, it could take over 5 minutes to load.

Version 2.03

New Features

Invert DC Signal

It is now possible to invert the 0 to 10 V signal for variable DC cooling.

Internet Status

A new indicator has been added to the top bar showing your current internet connectivity status.

Changes

Reports

All reports have been improved.

Heat Mat Probe

The heat mat probe offset upper and lower limits have eeach been increased by 1.5°C.

Bug Fixes

Growth Curves

An issue where days would be displayed incorrectly in specfic conditions has been fixed.

Go to top

Version 2.02

New Features

Misting and Fogging Humidity Bypass

A humidity probe can now be assigned in misting and fogging.

Changes

AutoFlex Help

The help library has been improved and expanded.

Reports

All reports have been improved.

DOL 15 Sensor

Support for the DOL 15 temperature sensor has been added.

Performance

General performance has been improved.

Go to top

Version 2.01

Changes

AutoFlex Help

The help library has been improved and expanded.

My Report

My Report has been updated to include charts.

Factory Reset

Factory reset now erases all configuration, settings, and history.

Go to top

Version 2.00

New Features

Manual Lighting Calibration

It is now possible to manually calibrate lighting controls.

Lighting Test Ramp

A new test ramp procedure starts lights at their lowest setting and gradually increases to their max setting. This allows you to test for flickering in the lighting calibration.

Minimum Ventilation Curves

Variable fans can now have a minimum ventilation curve to gradually increase or decrease idle speed.

Changes

AutoFlex Help

The help library has been improved and expanded.

My Report

My report has been updated to include charts.

Factory Reset

Factory reset now erases all configuration, settings, and history.